卡间集合通信参数不一致(EI0005)

问题现象

执行日志报错:EI0005“The arguments for collective communication are inconsistent between ranks”,如下所示。

custom_group :None
test_type : sum
dtype :float32
data :1024
fusion :0
fusion_id :1
fusion_num :2
iter :1
profiling :false
para_err_type :1
pid :1052803
ranksize is 8, rankid is 4.
time start: 2024-04-24 06:32:20.702705
ERROR : GeOp3_OGEOP::::DoRunAsync Failed
Error Message is:
EI0005: 2024-04-24-06:32:27.781.599 The arguments for collective communication are inconsistent between ranks:tag[HcomAllReduce_6629421139219749105_0],parameter[count],local[16512],remote [8320]
        Solution: Check whether the training script and ranktable of each NPU are consistent.
        TraceBack (most recent call last):
        Transport init error. Reason: [Create] [DestLink]Create Dest error! creakLink para:rank[5]-localUserrank[4]-localIpAddr[192.1.1. 243], dst_rank[6]-remoteUserrank[7]-remote_ip_addr[192.1.1.243]
        Transport init error. Reason: [Create] [DestLink]Create Dest error! creakLink para:rank[5]-localUserrank[4]-localIpAddr[192.1.1. 243], dst_rank[4]-remoteUserrank[5]-remote_ip_addr[192.1.1.243]
        call hccl op:HcomAllReduce(HcomAllReduce) load task fail[FUNC:Distribute][FILE:hccl_task_info.cc] [LINE:329]
        [[{[node Ge0p3_0]}]]
train fail
pid is 1052803

原因分析

该报错是本端和对端的校验参数不一致导致,问题一般出现在建链阶段。建链阶段本端接收到对端发过来的校验帧,然后和本端数据进行对比校验,确认数据是否一致。

通常原因是上层框架或用户调用传参有问题(取决于HCCL上层为框架还是用户直调),需要结合报错提示的“tag”确定出错算子,“parameter”确定出错算子参数。

解决方法

  • 若是用户直调出错集合通信算子,请根据错误信息中的"parameter"字段,确认算子接口入参的正确性。
  • 若是HCCL上层框架调用场景,您可以获取日志后单击Link联系技术支持。